Rotating Machines

Armature Winding in DC Machine

DC Machine

Armature Winding in DC Machine: With reference to the single-coil elementary Armature Winding in DC Machine of Figs 5.13 and 5.14(a) which shows the B-wave of the machine relative to the elementary full-pitched coil, LetConsider that the coil is lying in the interpolar region so that the full flux/pole (Φ) links it positively. Let it […]

Armature Winding in DC Machine Read More »

Short Pitch Coil or Chorded Coil

Short Pitched Coils

Short Pitch Coil or Chorded Coil: Short Pitch Coil – So far it was assumed that the stator coils are full-pitched (a span of π rad elect). Coils may have a span of less than the full-pitch. This arrangement offers certain advantages. Consider that the coil-span is less than the full-pitch by an elect. angle

Short Pitch Coil or Chorded Coil Read More »

EMF Equation of AC Winding

Generated Voltage of ac Winding

EMF Equation of AC Winding: The B-wave of a EMF Equation of AC Winding synchronous machine (in general multi-polar) assumed sinusoidal is drawn in Fig. 5.15 and a single full-pitched coil (coil-side space separation π rad (180°) elect.) is shown in cross-sectional form. The B-wave moves towards left with a speed of ω elect. rad/s

EMF Equation of AC Winding Read More »

2 Pole Elementary DC Machine

DC Machine

2 Pole Elementary DC Machine: Figure 5.13 shows a 2 Pole Elementary DC Machine with a single coil rotating armature. It may be seen that the field winding is stationary with salient poles whose pole-shoes occupy a major part of the pole-pitch. An alternating emf is induced in the coil due to rotation of the

2 Pole Elementary DC Machine Read More »

Three Phase Synchronous Generator

Three-phase Generator (Alternator)

Three Phase Synchronous Generator: Practical synchronous generators are always of the 3-phase kind because of the well-known advantages of a 3-phase system. If two coils were located at two different space locations in the stator of Fig. 5.2, their emfs will have a time phase difference corresponding to their electrical space displacement. In Three Phase

Three Phase Synchronous Generator Read More »

Rotating Electrical Machines

Rotating Electrical Machines

Rotating Electrical Machines: We Know that electromechanical energy conversion takes place whenever a change in flux is associated with mechanical motion. Speed voltage is generated in a coil when there is relative movement between the coil and magnetic field. Alternating emf is generated if the change in flux linkage of the coil is cyclic. The

Rotating Electrical Machines Read More »