Symmetrical Fault Analysis:

Algorithm for Short Circuit Computation : So far we have carried out short circuit calculations for simple systems whose passive networks can be easily reduced. In this section we extend our study to large systems. In order to apply the four steps of Algorithm for Short Circuit Computation developed earlier to large …


Introduction to Symmetrical Fault in Power System : Introduction to Symmetrical Fault in Power System devoted to abnormal system behaviour under conditions of symmetrical short circuit (symmetrical three-phase fault). Such conditions are caused in the system accidentally through insulation failure of equipment or flashover of lines initiated by a lightning stroke or …


Selection of Circuit Breaker : There are two types of Selection of Circuit Breaker ratings which require the computation of SC current are: (i) rated momentary current and (ii) rated symmetrical interrupting current. Symmetrical SC current is obtained by using subtransient reactances for synchronous machines. Momentary current (rms) is then calculated by multiplying …


Short Circuit Current Computation through Thevenin Theorem : An alternate method of computing Short Circuit Current Computation is through the application of the Thevenin theorem. This Short Circuit Current Computation method is faster and easily adopted to systematic computation for large networks. While the method is perfectly general, it is illustrated here …


Short Circuit of a Synchronous Machine (On No Load): Short Circuit of a Synchronous Machine – Under steady state short circuit conditions, the armature reaction of a synchronous generator produces a demagnetizing flux. In terms of a circuit this effect is modelled as a reactance Xa in series with the induced emf. …


Short Circuit of Loaded Synchronous Machine : In the previous article on the short circuit of a synchronous machine, it was assumed that the machine was operating at no load prior to the occurrence of short circuit. The analysis of Short Circuit of Loaded Synchronous Machine is complicated and is beyond the …


Transient on a Transmission Line : Let us consider the short circuit Transient on a Transmission Line. Certain simplifying assumptions are made at this stage. The line is fed from a constant voltage source (the case when the line is fed from a realistic synchronous machine. Short circuit takes place when the line is …


ZBUS Formulation : ZBUS Formulation is given by By Inventing YBUS The sparsity of YBUS may be retained by using an efficient inversion technique and nodal impedance matrix can then be calculated directly from the factorized admittance matrix. Current Injection Method: Equation (9.33) can be written in the expanded form It immediately follows from Eq. (9.34) that Also …