Three phase Generator Working

Three phase Generator Working

Three phase Generator Working – Practical synchronous generators are always of the 3-phase kind because of the well-known advantages* of a 3-phase system. If two coils were located at two different space locations in the stator of Fig. 5.2, their emfs will have a time phase difference corresponding to their electrical space displacement. If three coils are located in the stator of the 2-pole machine of Fig. 5.2 at relative electrical spacing of 120° (or 2/r/ 3 rad), an elementary 3-phase machine results as is shown in Fig. 5.11(a). The corresponding 4-pole arrangement is depicted in Fig. 5.11(b) where each phase has two symmetrically placed coils corresponding to each pair of poles. The coils of each phase are series/parallel connected and the three phases of a synchronous generator are generally connected in star as shown in Figs 5.12(a) and (b).

Three phase Generator Working

Three phase Generator Working

The process of torque production in a machine will be explained in Sec. 5.5 after gaining some familiarity with the rotating magnetic field produced by a current-carrying 3-phase winding.

MORE RELATED ARTICLE

COPYRIGHT © 2014 TO 2018 EEEGUIDE.COM ALL RIGHTS RESERVED | HOME | SITEMAP | CONTACT US | ABOUT US | PRIVACY POLICY | Frontier Theme